Table 2.

Sequence parameters for tissue phase mapping and cine balanced steady-state free precession (bSSFP) imaging

Tissue phase mapping Cine bSSFP
In-plane resolution [mm2] (1.6–2.5)2 (0.7–1.1)2
Slice thickness [mm] 5–8 4–8
Temporal resolution (range) [ms] 23.6±0.6 (21–25) 28.5±5.0 (15–38)
Electrocardiogram gating method Prospective Retrospective
Imaging acceleration kt-GRAPPA, R=5 GRAPPA, R=2
Breath-hold time (range) [heart beats/slice] 26±2 (20–32) 13±3 (9–27)
Breath-hold time (range) [seconds/slice] 21.0±3.4 (11–26) 10.6±1.4 (6–14)
Repetition time [ms] 5.2–6.2 2.6–3.3
Echo time [ms] 3.4–3.8 1.1–1.4
Flip angle 10°/15° 67–90°
Bandwidth [Hz/pixel] 455/650 920–945
Velocity encoding [cm/s] 25 N/A

N/A not available, GRAPPA generalized autocalibrating partial parallel acquisition