Skip to main content
. 2019 Dec 30;20(1):202. doi: 10.3390/s20010202

Table 3.

Minimum strength of the electric field (Etag) required to read the UHF RFID tags of differing sensitivities (Ptag), operating at a frequency of 865 MHz.

Tag Sensitivity (Ptag), W (dBm) Minimum Strength of the Electric Field (Etag) Required to Read the Tag, V/m
0.00001 (−20) 0.6
0.000016 (−18) 0.8
0.000025 (−16) 1.0
0.00004 (−14) 1.3
0.000063 (−12) 1.6
0.0001 (−10) 2.0