Skip to main content
. 2020 Jan 28;11:544. doi: 10.1038/s41467-020-14412-y

Fig. 6. Neutron time-of-flight data frome experiment.

Fig. 6

The neutron time-of-flight signal (red) from shot 80691 is obtained from two separate neutron time-of-flight (nTOF) diagnostics positioned 12 and 13.4-m, respectively, from target chamber center (TCC). A forward-fit approach (dashed-red), shown for the DD reaction, using a relativistic energy distribution is used to analyzed the time-of-flight signal to infer the yield and neutron-average ion temperature.