Stacking fault energies (SFE, mJ/m2) averaged at corresponding strain ranges in AM SS 316 L and AM CrCoNi alloys. The strain rates during tensile loading were marked in parenthesis.

SFE, γ (mJ/m2)
Strain (ε) SS316L (2 × 10−5) Strain (ε) CrCoNi (2 × 10−5) CrCoNi (2 × 10−3)
0.10–0.45 32.8 ± 8 0.01–0.40 15.1 ± 4 13.3 ± 4
0.10–0.23 46.1 ± 10 0.01–0.12 23.9 ± 8 22.6 ± 8
0.23–0.45 20.8 ± 2 0.12–0.40 11.1 ± 2 10.4 ± 2