Skip to main content
. Author manuscript; available in PMC: 2020 Nov 1.
Published in final edited form as: Forensic Sci Int. 2019 Sep 13;304:109939. doi: 10.1016/j.forsciint.2019.109939

Table 2.

Results of agreement between the outer packaging and the extract for the 144 exhibits analyzed.

Outer Packaging Extract Percent Occurrence Result Type
Drug Detected Same Drug Detected 32% (n = 46) True Positive
Drug Detected No Drug Detected 1% (n = 1) False Positive
Drug Detected Different Drug Detected 13% (n = 19) False Positive
No Drug Detected Drug Detected 43% (n = 62) False Negative
No Drug Detected No Drug Detected 11% (n = 16) True Negative
Overall Accuracy: 43%