Table 2. Diagnostic Performances of Different Parameters of SWV with and without QM.

Parameters Cut-Off Value Sensitivity Specificity AUC
SD − QM > 1.11 186/209 (89.0) 143/159 (89.9) 0.924
SD + QM > 0.83 185/209 (88.5) 143/159 (89.9) 0.912
p value 1 1 0.010*
SWVmean − QM > 3.04 m/s 176/209 (84.2) 144/159 (90.6) 0.912
SWVmean + QM > 3.12 m/s 186/209 (89.0) 141/159 (88.7) 0.932
p value 0.012* 0.625 < 0.001*
SWVmax − QM > 4.73 m/s 186/209 (89.0) 141/159 (88.7) 0.923
SWVmax + QM > 4.73 m/s 186/209 (89.0) 142/159 (89.3) 0.922
p value 1 1 0.550

Data are number of findings. Numbers in parentheses are percentages. *Indicates significant difference. AUC = areas under receiver operating characteristic curve, QM = quality map, SD = standard deviation, SWV = shear-wave velocity, SD − QM = SD without guidance of QM, SD + QM = SD with guidance of QM, SWVmean − QM = mean value of SWV without guidance of QM, SWVmean + QM = mean value of SWV with guidance of QM, SWVmax − QM = max value of SWV without guidance of QM, SWVmax + QM = max value of SWV with guidance of QM