TABLE I.

Time and energy resolution performance: ΔEexp, experimental energy resolution, including optical elements broadening and analyzer resolution; the electrons and photons per second are provided for the space charge free condition allowing for the overall energy resolution of 22 meV (9 pA at 16.9 eV and 200 kHz); Δtexp, experimental time resolution, measured as convolution between pump and probe pulses; ΔEprobe, harmonic bandwidth, after deconvolution of temperature and analyzer contribution; Δtprobe probe pulse time duration; ΔtFT, estimation of Fourier transform pulse duration, obtained considering a time-bandwidth product 0.44.

Parameter Value
Photon energy (eV) 16.9
Rep. Rate (kHz) 200
ΔEexp (meV) 22
Electrons/s 3 × 107
Photons/s 5 × 108
Δtexp (fs) 300
ΔEprobe (meV) 19
Δtprobe (fs) 105
ΔtFT (fs) 96