Skip to main content
. 2019 Sep 11;59(1):37–44. doi: 10.2169/internalmedicine.3413-19

Table 2.

The Impact of EVT on Peripheral Blood Pressure in Patients with PAD.

Variables Pre-EVT
n=60
Post-EVT
n=60
p value
Peripheral SBP (mmHg) 138±20 130±20 0.024
Peripheral DBP (mmHg) 67±13 62±12 0.055
Peripheral MBP (mmHg) 91±12 84±13 0.015
Pulse pressure (mmHg) 72±18 68±18 0.238
Heart rate (bpm) 71±18 72±13 0.818

Data are expressed as mean±SD.

DBP: diastolic blood pressure, EVT: endovascular therapy, MBP: mean blood pressure, PAD: peripheral artery disease, SBP: systolic blood pressure