Table 2.
Advantages and Disadvantages of the Demonstrated Techniques for Discovery, Exposure, and Repair of Partial-Thickness Rotator Tendon Tears
| Advantages | Disadvantages |
|---|---|
| Minimally invasive | Aggressive debridement and suction use can cause iatrogenic injury to the tissue |
| Standard arthroscopic setup and familiar portals | |
| Special equipment not required | The features indicating possible partial-thickness tears can be subtle and easily missed without considerable experience |
| Low-risk techniques to improve visualization |