Skip to main content
. 2016 Oct 27;122(1):68–75. doi: 10.1152/japplphysiol.00714.2016

Table 2.

Muscle, strength, and physical performance in HipFx before and after 3 mo of a multicomponent exercise training program and in comparison to matched, healthy older controls (CON)

Pre Post
HipFx
    Quad CSA, cm2 35.5 ± 13.7 39.3 ± 13.4*
    Muscle quality, N/cm2 8.6 ± 1.9 9.1 ± 1.3
    Force, N 315.7 ± 168.5 358.2 ± 125.6*
    Power, W 108.7 ± 73.8# 118.8 ± 55.8
    6MW, m 370.0 ± 159.0# 454.4 ± 149.0*#
CON
    Quad CSA, cm2 45.5 ± 15.4
    Muscle quality, N/cm2 8.7 ± 2.3
    Force, N 404.2 ± 196.3
    Power, W 164.7 ± 104.2
    6MW, m 539.8 ± 69.2

Data are means ± SD. Quadriceps (Quad) cross-sectional area (CSA), force and power in HipFx (n = 7) are data reported in the surgical leg, whereas in the healthy CON (n = 7) the data are an average of left and right legs. Quad CSA data were only acquired in 5 HipFx and 7 CON participants (see materials and methods). 6MW, 6-min walk.

*

Different from Pre.

#

Different from CON.