Study & Year Field Strengthen (T) Sequences Scanner type Machine Contrast agent No. of imaging planes MST (mm)
Brendle (2016) 3 T2WI/STIR/DWI Siemens Biograph mMR none 2 5
Cantwell (2008) 1.5 T1WI/T2WI/DCE-MRI GE/Siemens Signa Advantage/Magnetom Gd-related 2 5
Chiaradia (2014) 1.5 T1WI/T2WI/IVIM-DWI/DCE-MRI Siemens Avanto Gd-related 3 3
Cho (2015) 1.5 or 3 T1WI/T2WI/DWI/DCE-MRI Philips Intera Achieva Gd-related 2 2
Colagrande (2016) 1.5 T1WI/T2WI/DWI/DCE-MRI Philips Achieva Gd-related 1 4
Hwang (2018) 3 T1WI/T2WI/DWI/DCE-MRI Philips InteraAchieva Gd-related 3 NR
Kartalis (2011) 1.5 T1WI/T2WI/DCE-MRI Siemens Magnetom Avanto Gd-related 3 1.5
Kong (2008) 1.5 T1WI/T2WI/CE-MRI Philips Gyroscan Intera Master MnDPDP 2 7
Mainenti (2010) 1.5 T1WI/T2WI/DCE-MRI Philips Gyroscan Intera Gd-related/SPIO 2 4
Oba (2018) NR DCE-MRI NR NR Gd-related NR NR
Rappeport (2007) 1.5 T1WI/T2WI/DCE-MRI GE Horizon Signa LX SPIO 2 6
Rojas (2014) 1.5 DCE-MRI GE Signa Gd-related 1 2
Said (2000) 0.5/1.5 T1WI/T2WI/STIR/DCE-MRI Picker/GE Vista Hi Q/Signa SPIO 1 7
Schulz (2016) 1.5 T1WI/T2WI/DWI/SPIR/DCE-MRI Philips Achieva Gd-related 2 4
Shiozawa (2017) 1.5 T1WI/T2WI/DWI/DCE-MRI GE Signa Lx Gd-related 2 NR
Sivesgaard (2018) 1.5 T2WI/DWI/PDFF/DCE-MRI Philips Ingenia Gd-related 2 4
Zerhouni (1996) 1.0/1.5 T1WI/T2WI/STIR NR NR none 1 10

DCE: dynamic contrast-enhanced; DWI: diffusion-weighted imaging; Gd: Gadolinium; GE: General Electric Company; MnDPDP: manganese dipyridoxyl diphosphate; MRI: magnetic resonance imaging; NR: not reported; PDFF: proton density fat fraction; SPIO: superparamagnetic iron oxide; SPIR: spectral presaturation with inversion recovery; MST: minimum slice thickness; STIR: short time inversion recovery; T1WI: T1-weighted imaging; T2WI: T2-weighted imaging.