Table 2.
Parameters of interest for the MRE assessment of bowel inflammation in Crohn’s disease and corresponding MRE findings.
| MRE parameter | Definition/cut-off value |
|---|---|
| DWI | Hyperintense signal at a b-value of 800 s/mm |
| Mean ADC | ROI at 10-30 mm2 |
| Wall thickening | ≥ 3 mm |
| Intramural edema | Hyperintense signal on fat-saturated T2-weighted images |
| Ulcerations | Appear as small focal breaks in the intraluminal surface of the bowel |
| Stricture | Upstream lumen > 3 cm |
| Hyperenhancement | Attenuation on a contrast-enhanced scan higher in a segment that is not contracted than in nearby small bowel segments that are normal |
| MaRIA | ≥ 11 |
| Clermont score | ≥ 12.5 |