Skip to main content
. 2020 Feb 10;20:48. doi: 10.1186/s12903-020-1035-7

Table 2.

Inter-rater agreement for different reconstruction voxel sizes using the intraclass correlation coefficient (ICC)

V1 = 76 μm3 V2 = 100 μm3 V3 = 200 μm3
Tb.N 0.823 0.840 0.813
Tb.Sp 0.804 0.853 0.876
Tb.Th 0.883 0.819 0.837
BV/TV 0.829 0.871 0.845

Trabecular number (Tb.N), separation (Tb.Sp), thickness (Tb.Th), and bone volume fraction (BV/TV)

V = Voxel size

*p < 0.05