Skip to main content
. 2020 Jan 30;2020:6747498. doi: 10.1155/2020/6747498

Table 2.

Adhesion values of the six groups tested. Shear bond strength has been measured in MPa (conditions: untreated enamel, enamel after hypomineralization treatment, and enamel after hypomineralization and remineralization treatments).

Group Appliance Enamel Mean St Dev Min Mdn Max Significance
1 Bracket Intact 20.73 8.97 10.02 18.78 37.87 A, D
2 Bracket Demineralized 4.68 1.38 2.67 4.52 7.54 B
3 Bracket Demineralized and remineralized 12.31 3.91 6.98 12.03 20.41 C
4 Attachment Intact 27.82 3.61 20.09 28.08 34.12 A
5 Attachment Demineralized 6.35 1.54 3.09 7.04 7.70 B
6 Attachment Demineralized and remineralized 19.77 7.23 13.63 15.66 34.02 C, D

Tukey grouping-means with the same letters are not significantly different.