Processing conditions for the laser cleaning treatment.

Laser Parameters Units Values
Wavelength nm 1064
Average Power W 30
Pulse Frequency kHz 30
Pulse Duration ns 50
Laser Scan Speed mm/s 2000
Hatch Distance µm 40
Strategy Line