Effect of background correction and normalization of spectra on multivariate methods, reported as coefficients of determination, in the case of Ca, values in parentheses show the effect of using the logarithms of the mass fractions.

Element Averaged Raw Spectra Background Corrected, Normalized
and Averaged Spectra
PLSR Lasso GPR PLSR Lasso GPR
Ca 0.82
(0.68)
0.84
(0.59)
0.86
(0.82)
0.86
(0.87)
0.84
(0.85)
0.83
(0.89)
Mg 0.73 0.71 0.75 0.79 0.75 0.78
K 0.60 0.64 0.60 0.64 0.65 0.66
N 0.48 0.56 0.41 0.51 0.65 0.51
P 0.18 0.16 0.26 0.14 0.21 0.28
Fe 0.69 0.63 0.64 0.77 0.76 0.72
Mn 0.15 0.07 0.01 0.21 0.55 0.13
Al 0.72 0.65 0.71 0.79 0.74 0.81
P (pa) 0.25 0.09 0.37 0.22 0.25 0.35
Humus 0.58 0.41 0.50 0.56 0.66 0.54
pH 0.86 0.77 0.93 0.91 0.92 0.95
mean 0.52 0.47 0.52 0.55 0.61 0.57
change 6% 31% 11%