Skip to main content
. 2019 Jun 17;32(2):101–107. doi: 10.1016/j.sdentj.2019.06.001

Table 2.

Material properties used in FE model (Geng et al., 2001).

Material Young’s modulus [MPa] Poisson’s ratio Yield strength [MPa]
Cancellous bone 700 0.35 4.7
Cortical bone 18,000 0.35 107
Titanium implant 117,000 0.36 480