Skip to main content
. 2019 Dec 19;12(1):27. doi: 10.3390/cancers12010027

Table 8.

Protein binding values for the test item in human, monkey and rat plasma. Data are presented as mean ± standard deviation (n = 3). Unbound fraction (fu) values (averages of the two tested concentrations) used for the unbound clearance estimation.

Species LNA-i-miR-221 Concentration
1 µM 10 µM Mean PPB Mean fu
Human 98.6 ± 0.32 98.5 ± 0.09 98.55 0.0145
Monkey 98.2 ± 0.39 99.05 ± 0.39 98.63 0.0138
Rat 98.5 ± 0.17 98.9 ± 0.17 98.70 0.0130

PPB = plasma protein binding; mean fu = (100 − mean PPB%)/100.