Skip to main content
. 2020 Jan 12;9(1):210. doi: 10.3390/jcm9010210

Table 3.

Reproducibility of right atrial strain assessment.

Mean Difference ± SD (%) CoV (%) ICC (95% CI)
Intraobserver
RA Es −2.05 ± 3.84 13.73 0.95 (0.86–0.98)
RA Ee −0.17 ± 2.23 16.95 0.97 (0.94–0.99)
RA Ea −1.98 ± 4.58 30.84 0.83 (0.62–0.92)
RA SRs −0.08 ± 0.32 26.02 0.82 (0.63–0.92)
RA SRe 0.02 ± 0.17 31.48 0.91 (0.80–0.96)
RA SRa 0.08 ± 0.29 25.66 0.85 (0.69–0.93)
Interobserver
RA Es 1.67 ± 6.23 23.86 0.87 (0.72–0.94)
RA Ee 1.22 ± 4.14 33.15 0.88 (0.74–0.94)
RA Ea 0.44 ± 3.44 25.26 0.93 (0.84–0.97)
RA SRs 0.01 ± 0.29 25.44 0.84 (0.66–0.93)
RA SRe 0.02 ± 0.20 37.04 0.88 (0.74–0.94)
RA SRa −0.03 ± 0.29 27.10 0.86 (0.70–0.93)

SD = standard deviation, CoV = coefficient of variation, ICC = intraclass correlation coefficient, RA Es/e/a and SRs/e/a = right atrial reservoir, conduit and booster pump strain, and associated strain rate.