Skip to main content
. 2020 Feb 13;24:50. doi: 10.1186/s13054-020-2751-8

Table 2.

Conventional biochemical criteria used to predict successful discontinuation of RRT

Test/parameter Value/cut-off Timing RRT modality Sn Sp OR AUROC Publication
Serum creatinine
299.68 umol/L Initiation CRRT 0.79 0.79 0.75 Yoshida et al. [17]
Not specified Initiation CRRT 0.59 Han et al. [18]
224 umol/L Discontinuation CRRT 0.72 0.77 0.76 Chen et al. [19]
Per umol/L increase Discontinuation CRRT 0.48 Frohlich et al. [20]
Not specified Discontinuation CRRT 0.64 Uchino et al. [21]
Not specified Discontinuation CRRT 0.73 Katayama et al. [22]
2-h creatinine clearance
23 mL/min 12 h pre-stop Not specified 1.11 0.82 Frohlich et al. [20]
Residual creatinine clearance
Not specified 24–48 h pre-stop Not specified 0.90 Gleeson et al. [23]
Kinetic eGFR
20.58 mL/min/1.73 m2 Discontinuation CRRT 0.71 0.92 0.87 Yoshida et al. [17]
eGFR
26.21 mL/min/1.73 m2 D1 post-stop CRRT 0.71 0.85 0.83 Yoshida et al. [17]
24 h urine creatinine
> 5.2 mol/24 h D0 post-stop CRRT, SLED, 0.57 0.96 0.76 Viallet et al. [26]
D1 IHD 0.75 0.88 0.86
D2 0.86 0.81 0.86
Urine urea
> 148 mmol/L Discontinuation IHD, CRRT 0.65 0.90 0.82 Aniort et al. [25]
Daily urinary urea excretion
> 1.35 mmol/kg/day Discontinuation IHD, CRRT 0.89 0.97 0.96 Aniort et al. [25]