Skip to main content
. 2020 Feb 14;11:26. doi: 10.1186/s13244-020-0835-2

Table 3.

BI-RADS categories of the 355 breast lesions detected on DBT and DM in relation to the final diagnosis

DBT DM
Malignant Benign Total Malignant Benign Total
Not seen 0 0 0 15 (4.2) 22 (6.2) 37 (10.4)
BI-RADS 0 0 0 0 4 (1.1) 11 (3.1) 15 (4.2)
BI-RADS 1 0 26 (7.3) 26 (7.3) 0 0 0
BI-RADS 2 0 96 (27) 96 (27) 0 0 0
BI-RADS 3 16 (4.5) 65 (18.3) 81 (22.8) 30 (8.5) 107 (30.1) 137 (38.6)
BI-RADS 4 a 16 (4.5) 6 (1.8) 22 (6.3) 66 (18.6) 67 (18.9) 133 (37.5)
BI-RADS 4 b 19 (5.4) 0 19 (5.4) 11 (3.1) 0 11 (3.1)
BI-RADS 4 c 34 (9.6) 14 (3.9) 48 (13.5) 22 (6.2) 0 22 (6.2)
BI-RADS 5 63 (17.7) 0 63 (17.7) 0 0 0
Total 148 (41.7) 207 (58.3) 355 (100) 148 (41.7) 207 (58.3) 355 (100)

The data are represented as numbers with the corresponding percentages given in parentheses

DBT digital breast tomosynthesis, DM digital mammography, BI-RADS Breast Imaging Reporting and Data System