Table 2.
Performance of the PHQ-2 in detecting depressive disorder among patients in routine care* (N=1 206)
| Cut-point | Sensitivity (%) | Specificity (%) | Correctly classified (%) | LR+ | LR− |
|---|---|---|---|---|---|
| ≥0 | 100 | 0 | 4.73 | 1.00 | 0.00 |
| ≥1 | 92.98 | 26.28 | 29.44 | 1.26 | 0.27 |
| ≥2 | 78.95 | 49.26 | 50.66 | 1.56 | 0.43 |
| ≥3 | 57.89 | 77.37 | 76.45 | 2.56 | 0.54 |
| ≥4 | 42.11 | 86.86 | 84.74 | 3.20 | 0.67 |
| ≥5 | 17.54 | 93.56 | 89.97 | 2.72 | 0.88 |
| ≥6 | 12.28 | 95.74 | 91.79 | 2.88 | 0.92 |
| >6 | 0 | 100 | 95.27 | 1.00 | 1.00 |
PHQ-2 = Patient Health Questionnaire; LR+ = likelihood ratio positive; LR− = likelihood ratio negative.
Adult Primary Care assessment by the primary healthcare nurse was used as a diagnostic reference standard.