Skip to main content
. 2020 Feb 7;9(2):e239–e245. doi: 10.1016/j.eats.2019.10.003

Table 1.

Pearls and Pitfalls

Pearls Pitfalls
  • During the surgical approach, perform careful dissection, especially in cases with previous surgery and scar formation.

  • Ensure accurate size matching of recipient and donor sites and use demineralized bone matrix as adjuvant filler.

  • During capsulotomy of the proximal limb along the acetabular rim, an inside-out technique should be used to avoid damage to the labrum.

  • Femoral head damage from aberrant retractor placement.

  • Retinacular vessel and other vascular damage from excessive use of electrocautery.

  • Labral damage from inadequate distraction during dislocation.

  • Incongruence of the articular surface from countersinking of the allograft.