Skip to main content
. 2020 Jan 15;7(1):191127. doi: 10.1098/rsos.191127

Table 2.

Ratio of relative standard deviation in power to relative input standard deviation for three different values of σ^Cd={0.1,0.3,0.5} at optimal and half-optimal turbine drag values (columns) and different fence configurations and mean bed roughness coefficients (rows).

σ^P/σ^Cd (%)
1/2Ct,det Ct,det
ABC μCd=0.0025 20, 20, 20 15, 15, 15
 fully μCd=0.005 33, 33, 34 24, 24, 24
 spanned μCd=0.016 60, 62, 64 44, 45, 46
A μCd=0.0025 29, 29, 29 23, 23, 23
 asymmetrically μCd=0.005 42, 43, 44 33, 33, 34
 confined μCd=0.016 64, 67, 73 49, 51, 54
B μCd=0.0025 21, 21, 20 17, 17, 16
 laterally μCd=0.005 34, 35, 34 27, 27, 27
 unconfined μCd=0.016 61, 63, 67 48, 49, 51