TABLE I.

Comparison of parameter percent biases at iteration 400 between direct and indirect results for the noise-free canine simulation. K1, K1,uncorr, k2 and VL values were measured as the average within two VOIS: whole LV myocardium and LVES myocardium.

Bias @ Iter 400 K1 K1,uncorr k2 VL
Whole LV Myo Direct 3.3% −7.5% 15.0% 40.5%
Indirect −2.3% −7.8% 11.0% 23.5%
LVES Myo Direct −2.3% −3.8% 19.0% 3.0%
Indirect −11.3% −10.0% 6.0% −6.0%