Experimental range and levels of independent parameters.

Parameters Symbol Variable levels
Low (−1) Central point (0) High (+1)
SHL content [% w/w] X1 35.0 37.5 40.0
ML content [% w/w] X2 1.0 2.0 3.0
Applied voltage [kV] X3 9.0 18.0 27.0
Flow rate [ml/h] X4 0.4 0.8 1.2