Skip to main content
. 2020 Feb 4;5(6):2620–2629. doi: 10.1021/acsomega.9b02989

Table 1. Corrosion Parameters of PDDB and PDHDB Obtained from Weight Loss Measurements for Carbon Steel in 1.0 mol·L–1 HCl.

inhibitor C/mol·L–1 v/mm·y–1 θ η (%)
HCl 0 4.9945 ± 0.1258    
PDDB 1.0 × 10–6 2.9201 ± 0.0119 0.42 ± 0.01 41.6 ± 0.2
3.0 × 10–6 1.7116 ± 0.0501 0.66 ± 0.01 65.7 ± 1.0
6.0 × 10–6 1.6018 ± 0.0066 0.68 ± 0.01 67.9 ± 0.2
1.0 × 10–5 1.0839 ± 0.1095 0.78 ± 0.02 78.4 ± 2.4
3.0 × 10–5 0.6813 ± 0.0573 0.86 ± 0.02 86.3 ± 1.2
PDHDB 1.0 × 10–6 2.5153 ± 0.0692 0.49 ± 0.01 49.4 ± 1.2
3.0 × 10–6 1.6220 ± 0.0459 0.68 ± 0.01 67.5 ± 0.9
6.0 × 10–6 1.3084 ± 0.1115 0.75 ± 0.01 74.5 ± 1.5
1.0 × 10–5 0.8670 ± 0.0678 0.83 ± 0.02 82.7 ± 1.4
3.0 × 10–5 0.5742 ± 0.0686 0.89 ± 0.02 88.5 ± 1.3