Table 3.
Requirements EN 1891 for Low Stretch Kernmantle Ropes | Requirements EN 892 for Dynamic Ropes | ||
---|---|---|---|
Diameter | 8.5–16 mm | Percentage of core | ≥50 % |
Elongation 50–150 kg | ≤5% | Elongation 80 kg | ≤8% |
Impact force FF = 0.3 (100 kg) | <6 kN | Impact force | ≤12 kN |
Number of falls FF = 1 (100 kg) | ≥5 | Number of falls FF = 2 (80 kg) | ≥5 |
Static strength | ≥22 kN type A (work ropes) | - | - |
≥18 kN type B (sports rope) |