TABLE 7.
Results of linear regression analysis, with AzBio sentence recognition in quiet as the outcome measure. Only pure-tone average (PTA) was entered as predictor
AzBio Sentences in Quiet (% Words Correct) | B | SE (B) | β | t | Sig. (p) | R2 | R2 Change |
---|---|---|---|---|---|---|---|
Predictor: | 0.197 | 0.197 | |||||
PTA (dB HL) | −0.653 | 0.259 | −0.444 | −2.53 | 0.018 |
HL indicates hearing level; PTA, pure-tone average.