Table 7.
# | Material | Protective Parameter | Performance Level in Accordance with EN ISO 11612:2015 [50] | Change in Sample Thickness X, mm | Mean of X, mm (SD) |
|
---|---|---|---|---|---|---|
Mass of Metal Poured, g | Molten Metal Splash Index | |||||
1 | ASP | 220 220 220 |
>200 | E3 | 18 15 18 |
17 (2) |
2 | AP | 220 220 220 |
>200 | E3 | - | - |
3 | A | 220 220 220 |
>200 | E3 | - | - |
SD—standard deviation. Note: For protective parameters (“mass of metal poured” and “molten metal splash index”), the mean and standard deviation (SD) were not calculated, because these parameters were obtained by trial-and-error by repeating the procedure of pouring a smaller or larger amount of metal, until the minimum amount of metal that initiated PVC (polyvinyl chloride) film damage was determined.