Skip to main content
. 2019 Feb 18;26(1):20–25. doi: 10.4103/sjg.SJG_411_19

Table 2.

Quantitative analysis of ADC values of the collection

ADC values from the content and wall of collection Infected (n=7) × 10-3 mm2/s Sterile (n=11) × 10-3 mm2/s P
ADC value from the content (Minimum), Median (IQR) 1.488 (1.862) 2.944 (1.709) 0.085a
ADC value from the content (Maximum), Median (IQR) 2.077 (1.760) 3.378 (1.213) 0.069a
ADC value from the content (Mean), Median (IQR) 1.767 (1.841) 3.161 (1.472) 0.104a
ADC value from the wall (Minimum), Median (IQR) 0.898 (0.481) 1.735 (0.678) 0.004 a
ADC value from the wall (Maximum), Median (IQR) 1.423 (0.403) 2.541 (0.845) 0.003a
ADC value from the wall (Mean), Median (IQR) 1.091 (0.437) 2.184 (0.633) 0.004a

aMann-Whitney U test; ADC: Apparent diffusion coefficient. P value of less than 0.05 is significant