Table 2. The relationship between the airway diameter, mucus score, and spirometry measures.
Spirometry value | Total bronchial area Din (mm) | Total bronchial area mucus plug (number) |
---|---|---|
FEV1 (% predicted) | NS | −1.1 (−1.9, −0.3) |
R2 = 0.42, P = 0.0162 | ||
FVC (% predicted) | NS | NS |
FEV1/FVC | NS | −0.6 (−1.1, −0.2) |
R2 = 0.51, P = 0.0064 |
NS, not significant