Skip to main content
. Author manuscript; available in PMC: 2020 Feb 28.
Published in final edited form as: Nat Electron. 2019;2(10):10.1038/s41928-019-0300-8. doi: 10.1038/s41928-019-0300-8

Figure 4.

Figure 4.

Critical current and inferred temperature versus input power density. As the input power density is increased, the effective temperature of the meander rises, and its critical current is reduced. The small discontinuity is an experimental artifact from measuring very small critical current values.