Table S1. Data quantifications.
Items | Groups | Power (1-β) | ||
---|---|---|---|---|
Control | 2.0 mm-stent | 1.5 mm-stent | ||
Diameter (mm) | ||||
4w | 1.94±0.09 | 1.72±0.03 | 1.38±0.07 | 1 |
8w | 2.13±0.07 | 1.58±0.05 | 1.25±0.09 | 1 |
Velocity (mm/s) | ||||
4w | 671.6±32.64 | 780.2±93.52 | 884.4±71.5 | 1 |
8w | 633±51.2 | 761.8±113.78 | 816.8±161.54 | 0.9999964 |
Wall thickness (mm) | ||||
4w | 129.06±23.2 | 89.94±14.76 | 57.17±12.91 | 0.9996988 |
8w | 157.38±28.8 | 96.77±18.33 | 61.27±7.14 | 0.9999565 |
Intima area (mm2) | ||||
4w | 0.78±0.07 | 0.63±0.05 | 0.3±0.05 | 1 |
8w | 1.02±0.21 | 0.74±0.13 | 0.32±0.07 | 0.9999497 |
Mean IOD of TNF-α | 0.137±0.007 | 0.088±0.008 | 0.046±0.005 | 1 |
Mean IOD of JNK | 0.013±0.001 | 0.012±0.001 | 0.005±0.001 | 1 |
Mean IOD of c-Jun | 0.013±0.002 | 0.007±0.001 | 0.003±0.001 | 1 |
TUNEL+ cells | 37.45±7.45 | 16.33±4.3 | 6.42±2.21 | 1 |
Data were presented as mean ± SD flowed by one-way ANOVA analysis. Statistical significances were represented on the relevant figures.