Skip to main content
. 2020 Feb 18;2020:5382739. doi: 10.1155/2020/5382739

Table 5.

Intubation details in scenario E cervical collar stabilization and pharyngeal obstruction. Data are presented as median (IQR) or as number (%).

Parameter A B C p values for between-device differences p
Macintosh McGrath TruView PCD A versus B A versus C B versus C
Success rate of intubation attempt (%) 14 (15%) 87 (94%) 53 (57%) <0.001 <0.001 <0.001 <0.001

Duration of 1st intubation attempt (s) 28 (25–39) 19 (18–26) 34 (27–45) 0.059 0.787 0.009 0.018

Cormack-Lehane grade 0 (0%) 79 (84%) 40 (43%) <0.001 <0.001 0.031 <0.001
1 31 (33%) 14 (16%) 53 (57%)
2 58 (62%) 0 (0%) 0 (0%)
3 4 (4%) 0 (0%) 0 (0%)
4 3 (2–3) 1 (1–1) 1 (1–2)
Median (IQR)

POGO score 45 (29–63) 98 (90–100) 92 (83–98) <0.001 <0.001 0.003 <0.001

Number of optimization manoeuvres (%) 10 (11%) 31 (33%) 19 (20%) <0.001 0.005 0.012 <0.001
0 21 (23%) 45 (48%) 37 (40%)
1 62 (67%) 17 (18%) 37 (40%)
2 2 (1–2) 1 (0–1) 1 (1–2)
Median (IQR)

Severity of dental compression (%) 0 (0%) 0 (0%) 0 (0%) <0.001 0.007 <0.001 <0.001
0 7 (8%) 90 (97%) 31 (33%)
1 86 (93%) 3 (3%) 62 (67%)
2 2 (2–2) 1 (1–1) 2 (1–2)
Median (IQR)

Ease of use (1–100) 68 (51–80) 31 (28–45) 51 (36–64) <0.001 <0.001 <0.001 <0.001