Ictal SPECT operational timings

Ictal SPECT timings Mean Range
From first clinical ictal sign to tracer injection 17 s 1‐65 s
From first EEG changes to injectiona 25 s 0‐289 s
From start of injection to complete injection of the tracer 13 s 4‐46 s
From the end of injection to seizure cessationb 61 s 0‐390 s
From tracer injection to ictal SPECT 40 min 13‐89 min
a

Injection was performed before the first EEG changes in three cases, while in one case there was no definite ictal EEG activity.

b

In seven cases, seizures ended before the end of injection (mean 9 s; 3‐20 s).