Table 1.

Test–retest reliability of standard and modified assessment protocols for timed-up-and-go, five-repetition sit-to-stand, handgrip strength, two-minute walk, and 30-second sit-to-stand physical assessments.

Physical assessment measure Published reliability of the standard protocol (ICC) ICC trial 1 to trial 3 on the first occasion of assessment (Cronbach’s α)a Participants able to complete modified protocol (%) Test–retest reliability (Pearson’s) Coefficient of variation (%)
Timed-up-and-go2 0.98 0.91 64 0.87 11.9
Five-repetition sit-to-stand3 0.81 0.95 64 0.75 12.7
Handgrip strength2 0.98 0.98 100 0.94 9.8
Two-minute walk8 0.98 b 64 0.87 b
Four-metre walk14 0.96 0.84 64 0.83 7.2
30-second sit-to-stand2 0.92 0.77 64 0.93 14.8

ICC: intraclass correlation coefficient.

a

ICCs were calculated from the three measures collected on the first test occasion.

b

The two-minute walk was completed once on each measurement occasion and does not have an ICC or coefficient of variation value.