Table 5. Comparison of the Radiographic Results.

Variable Gamma nail (n=72) U-blade Gamma nail (n=90) P-value
TAD (mm) 22.7 (12.4-38.9) 22.4 (11.32-39.17) 0.704*
 TAD over 25 mm 25 (34.7) 31 (34.4) 0.971*
Position of lag screw in Cleveland zone 0.092*
 Zone 5 43 (59.7) 66 (73.3)
 Others (zone 4, 6, 8, 9) 29 (40.3) 24 (26.7)
Fracture reduction 0.956*
 Anatomical 40 (55.6) 50 (55.6)
 Extramedullary 23 (31.9) 30 (33.3)
 Intramedullary 9 (12.5) 10 (11.1)
Fracture reduction by Baumgartner classification 0.786*
 Good 38 (52.8) 49 (54.4)
 Acceptable 29 (40.3) 35 (38.9)
 Poor 5 (6.9) 6 (6.7)
Sliding distance (mm) 4.7±3.68 3.6±2.81 0.025
Mean bone union duration (wk) 12.9±9.53 10.4±5.28 0.053

Values are presented as median (range), number (%), or mean±standard deviation.

TAD: tip-apex distance.

*Pearson chi-squared test; Student t-test.