Skip to main content
. 2020 Mar 4;10:4030. doi: 10.1038/s41598-020-60767-z

Figure 6.

Figure 6

Comparison of VSM and MFM data for the MgO(001)/Rh(1.1 nm)/FeRh(53 nm)/Pt(4.5 nm) film. The MFM data were extracted from heat maps showing the percentage area of film in the FM phase during heating and cooling cycles. The VSM data are included for comparison and plotted on the same percentage scale. The dashed lines show a smoothed spline between data points, and are included solely as indication of the data trend.