Skip to main content
. Author manuscript; available in PMC: 2020 Mar 4.
Published in final edited form as: Appl Sci (Basel). 2019 Apr 11;9(7):10.3390/app9071505. doi: 10.3390/app9071505

Table 3.

True Positive Rate (TPR), False Positive Rate (FPR) and Area Under the receiver operating characteristic Curve (AUC) of different classifiers for different voice types based on the full feature set.

DT LD SVM KNN NN
Modal TPR 0.73 0.70 0.79 0.77 0.81
FPR 0.14 0.13 0.11 0.11 0.10
AUC 0.85 0.89 0.92 0.92 0.93
Breathy TPR 0.84 0.87 0.89 0.89 0.90
FPR 0.10 0.10 0.09 0.09 0.08
AUC 0.89 0.95 0.96 0.96 0.97
Pressed TPR 0.69 0.75 0.74 0.75 0.91
FPR 0.10 0.10 0.08 0.08 0.16
AUC 0.86 0.91 0.92 0.93 0.94