Skip to main content
. 2020 Jan 28;15(8):1397–1407. doi: 10.4103/1673-5374.274326

Figure 5.

Figure 5

Placement of the electrodes in a SCI patients with LMN.

A rubber-based electrode is covered in a salt free gel (A) before being placed in a wet, conductive sponge (B) which prevents surface tissue damage. The covered electrode is then secured with elastic straps in position above the knee extensor groups (C). LMN: Lower motor neuron; SCI: spinal cord injury.