Skip to main content
. 2020 Mar 6;2020(2):hoaa001. doi: 10.1093/hropen/hoaa001

Table IV.

Inter- and intraobserver agreement for ultrasound assessment of mean nodule diameter.

Agreement Site Bland–Altman analysis ICC
Mean diff (*) 95% B-A limits (95% CI)
Interobserver All −1.3 −6.7, 4.2 0.69 (0.53, 0.80)
Posterior −1.7 −7.4, 4.0 0.41 (0.12, 0.65)
Bowel −0.4 −5.4, 4.6 0.88 (0.72, 0.95)
Intraobserver A All 0.1 −3.2, 3.5 0.91 (0.86, 0.94)
Posterior 0.1 −3.3, 3.4 0.86 (0.77, 0.92)
Bowel 0.5 −2.8, 3.8 0.96 (0.90, 0.98)
Intraobserver B All 0.0 −2.7, 2.6 0.95 (0.93, 0.97)
Posterior 0.3 −1.8, 2.5 0.93 (0.88, 0.96)
Bowel −0.9 −4.0, 2.2 0.93 (0.82, 0.97)

(*)Differences for interobserver variation calculated as Observer A − Observer B. Differences for intraobserver variation calculated as Measurement 1 – Measurement 2. N = 50 women.