Table 1.
Room configurations.
parameters | configurations | |||
---|---|---|---|---|
room | ||||
length × width × height | 8 m × 4 m × 3 m | |||
walls and ceiling reflection coefficient | 0.8 [48] | |||
floor reflection coefficient | 0.3 [48] | |||
number of reflections | 1 | 2 | ||
area of reflection element | 5 cm × 5 cm | 20 cm × 20 cm | ||
order of lambertian pattern, walls, floor and ceiling | 1 [48] | |||
semi-angle of reflection element at half-power | 60° | |||
transmitters | ||||
number of transmitters' units | 8 | |||
transmitters locations (x, y, z) | (1 m, 1 m, 3 m), (1 m, 3 m, 3 m), (1 m, 5 m, 3 m), (1 m, 7 m, 3 m), (3 m, 1 m, 3 m), (3 m, 3 m, 3 m), (3 m, 5 m, 3 m) and (3 m, 7 m, 3 m) | |||
number of RYGB LDs per unit | 12 | |||
transmitted optical power of red LD | 0.8 W | |||
transmitted optical power of yellow LD | 0.5 W | |||
transmitted optical power of green LD | 0.3 W | |||
transmitted optical power of blue LD | 0.3 W | |||
total transmitted power of RYGB LD | 1.9 W | |||
semi-angle at half-power | 60° | |||
Receiver | ||||
number of photodetectors | 4 | |||
area of the photodetector | 20 mm2 | |||
responsivity red | 0.4 A W−1 | |||
responsivity yellow | 0.35 A W−1 | |||
responsivity green | 0.3 A W−1 | |||
responsivity blue | 0.2 A W−1 | |||
photodetector | 1 | 2 | 3 | 4 |
azimuth angles | 45° | 135° | 225° | 315° |
elevation angles | 70° | 70° | 70° | 70° |
field of view (FOV) of each detector | 25° | |||
receiver noise current spectral density | 4.47 pA/√Hz [49] | |||
receiver bandwidth | 1.75 GHz |