Skip to main content
. 2020 Mar 3;14:66. doi: 10.3389/fnhum.2020.00066

Table 1.

Ultrasound plus sham participant results: categories of participants, which participants were in each category, and a brief summary of the results from participants for ultrasound paradigm.

Participant group Participants in group Results
Responsive (7 participants) Participant 1
Participant 2
Participant 3
Participant 7
Participant 8
Participant 10
Participant 11
4 total percepts, 2 “flashes” of the crosshair as the trial started. 2 images, both gray.
13 total percepts, blobs of gray color in an oblong or oval shape in 12/13 trials.
18 total percepts, 7 rectangles, 4 circles, 3 with lines.
3 total percepts, 2 trials where crosshair “flashed.”
13 total percepts, all were lines. During 3 trials participant reported percept before US stim had begun, during 2 trials participant reported percept approximately 40 s after the stimulation had ended.
2 total percepts, 2 lines that both lasted for 12 s.
6 total percepts, 4/6 were small dots
Non-Responsive (3 participants) Participant 4
Participant 6
Participant 9
N/A
Non-Responsive to TMS and to US (1 participant) Participant 5 N/A