Table 4.

Table depicting diagnostic accuracy of various magnetic resonance image pulse sequences

Parameter HASTEα axial HASTEα coronal TRUFIδ SPAIRβ 3D FLASHχ BLADEε
HALO sign
 Sensitivity 100% * * 100% * 100%
 Specificity 96.9% 100% 100% 96.9% 100% 96.9%
 NPV 100% 94.2% 94.2% 100% 94.2% 100%
 PPV 66.6% * * 66.6% * 66.6%
Nodules
 Sensitivity 50% 7% 42.8% 50% 28.5% 50%
 Specificity 95.2% 100% 95.2% 95.2% 100% 90.4%
 NPV 74% 61.7% 85.7% 74% 67.7% 73%
 PPV 87.5% 100% 71.4% 87.5% 100% 77.7%
Cavitating nodule
 Sensitivity 100% * 100% 100% 50% 100%
 Specificity 96.9% 100% 100% 96.9% 100% 100%
 NPV 100% 94.2% 100% 100% 97% 100%
 PPV 66.6% * 100% 66.6% 100% 100%
Consolidation
 Sensitivity 100% 77% 100% 100% 77% 100%
 Specificity 96% 100% 100% 96% 100% 100%
 NPV 100% 92.8% 100% 100% 92.8% 100%
 PPV 90% 100% 100% 90% 100% 100%
Consolidation with breakdown
 Sensitivity 100% 50% 100% 100% 50% 100%
 Specificity 96.9% 96.9% 96.9% 96.9% 96.9% 96.9%
 NPV 100% 96.9% 100% 100% 96.9% 100%
 PPV 66.6% 50% 66.6% 66.6% 50% 66.6%
GGOs
 Sensitivity 66.6% * 16.6% 77.7% 33.3% 55.5%
 Specificity 88.4% 92.8% 86.2% 76.9% 81.2% 96.1%
 NPV 88.4% 78.7% 83.3% 90.9% 92.8% 86.2%
 PPV 66.6% * 20% 53.8% 14.2% 83.3%
α

Half-Fourier acquisition single-shot turbo spin-echo.

δ

True fast imaging with steady-state free precession.

β

Spectrally attenuated inversion recovery.

χ

3-Dimensional fast low-angle shot.

ε

Proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction.

*

Not detected in this sequence. NPV – negative predictive value, PPV – positive predictive value, GGOs – ground-glass opacities