Skip to main content
. 2019 Jul 24;33(1):168–180. doi: 10.1007/s10278-019-00250-y

Table 2.

Performance of DRIVE Database—morphological based and local normalized illumination correction

Image Morphological based illumination correction (%) Local normalized illumination correction (%)
Sensitivity Specificity Accuracy Sensitivity Specificity Accuracy
1 85.06 97.47 96.42 80.71 96.78 95.60
2 89.00 97.75 96.73 83.88 96.15 95.17
3 88.82 94.63 94.16 81.80 94.85 94.03
4 84.48 97.53 96.23 85.44 95.87 95.22
5 92.10 96.74 96.36 85.40 95.62 94.99
6 91.05 96.51 96.05 85.00 95.09 94.48
7 89.70 97.19 96.55 82.58 95.93 95.07
8 87.84 96.68 96.01 83.71 95.46 94.86
9 89.55 96.79 96.34 83.38 96.17 95.48
10 87.04 98.00 97.11 81.21 96.61 95.65
11 85.48 97.73 96.68 78.31 96.02 94.83
12 85.70 95.93 95.25 82.07 96.13 95.27
13 89.06 97.62 96.78 83.49 95.95 95.05
14 80.90 98.21 96.69 77.49 96.21 95.12
15 82.10 97.67 96.67 74.80 97.30 95.91
16 86.15 97.37 96.40 83.40 96.48 95.58
17 84.70 96.84 95.92 81.70 96.44 95.52
18 83.08 97.86 96.68 79.54 97.04 95.90
19 86.03 98.54 97.47 82.32 97.41 96.33
20 82.72 98.02 96.93 78.15 97.22 96.07
Average 86.53 97.25 96.37 81.72 96.24 95.31