Skip to main content
. 2020 Mar 10;70(693):e245–e254. doi: 10.3399/bjgp20X708833

Table 2.

Sensitivity and specificity of the Centor and McIsaac scores at different thresholds

Threshold Sensitivity, % (95% CI) Specificity, % (95% CI) LR+ (95% CI) LR− (95% CI)
Centor score
1 97.2 (96.4 to 97.8) 10.1 (6.3 to 15.2) 1.08 (1.05 to 1.14) 0.28 (0.23 to 0.45)
2 84.4 (81.4 to 87.0) 36.7 (28.8 to 45.1) 1.33 (1.19 to 1.50) 0.43 (0.39 to 0.55)
3 54.4 (48.7 to 60.0) 72.4 (64.4 to 79.4) 1.97 (1.46 to 2.40) 0.63 (0.58 to 0.74)
4 21.5 (16.6 to 27.2) 93.7 (89.6 to 96.4) 3.41 (1.83 to 4.97) 0.84 (0.78 to 0.90)

McIsaac score
0 99.7 (99.0 to 99.9) 2.3 (0.3 to 10.7) 1.02 (1.00 to 1.10) 0.15 (0.09 to 0.35)
1 97.5 (94.7 to 99.0) 10.8 (2.8 to 28.4) 1.09 (1.02 to 1.30) 0.23 (0.17 to 0.39)
2 88.0 (82.0 to 93.8) 31.5 (14.2 to 54.3) 1.30 (1.09 to 1.76) 0.35 (0.28 to 0.47)
3 68.7 (57.4 to 78.5) 60.8 (39.9 to 78.8) 1.75 (1.28 to 2.79) 0.51 (0.44 to 0.58)
4 40.0 (28.5 to 52.5) 84.8 (70.8 to 93.4) 2.64 (1.68 to 4.95) 0.71 (0.62 to 0.78)
5 16.1 (8.9 to 26.2) 96.3 (90.8 to 98.7) 4.32 (2.38 to 10.0) 0.87 (0.79 to 0.93)

CI = confidence interval. LR+ = positive likelihood ratio. LR− = negative likelihood ratio.