Impedance and phase average and standard deviation values at 10 kHz and 1 MHz in pure material sets. Measurement X-direction (X), Y-direction (Y), and Z-direction (Z), (Figure 3).

Material 10 kHz 1 MHz
|Z| (Ω) φ (°) |Z| (Ω) φ (°)
Pine sapwood (X) 6.6 (0.7) −68.4 (13.0) 5.2 (0.3) −63.3 (9.1)
Pine heartwood (X) 7.5 (0.5) −67.8 (14.8) 5.8 (0.2) −77.9 (7.9)
Birch wood (X) 6.9 (0.6) −69.4 (10.5) 5.4 (0.3) −69.0 (10.5)
Birch bark (X) 6.1 (0.8) −60.4 (10.7) 4.8 (0.5) −53.8 (11.1)
Pine sapwood (Y) 6.6 (0.7) −67.9 (12.8) 5.2 (0.4) −63.1 (9.2)
Pine heartwood (Y) 7.4 (0.5) −67.3 (15.1) 5.8 (0.2) −78.0 (7.9)
Birch wood (Y) 6.9 (0.6) −69.4 (10.7) 5.4 (0.3) −69.4 (9.8)
Birch bark (Y) 6.0 (0.7) −61.1 (12.4) 4.7 (0.6) −50.9 (13.1)
Pine sapwood (Z) 6.3 (0.7) −63.6 (15.9) 5.1 (0.4) −64.5 (12.1)
Pine heartwood (Z) 5.6 (0.2) −80.5 (7.5) 5.6 (0.2) −80.5 (7.5)
Birch wood (Z) 6.6 (0.6) −66.7 (12.0) 5.2 (0.4) −70.4 (11.6)
Birch bark (Z) 6.0 (0.7) −74.5 (11.3) 4.5 (0.6) −56.3 (13.1)