Comparison of dark-lesion detection methods for the 45 retinal images with microaneurysms or hemorrhages of DIARETDB1 database.

Methods Sensitivity Specificity AUC
Rocha et al. [54] 0.9000 0.6000 0.7640
Roychowdhury et al. [55] 0.7550 0.9373 0.8263
Ashraf et al. [56] 0.6763 0.6278 0.6500
Junior and Welfer [57] 0.8769 0.9244 -
Proposed method 0.7561 ± 0.0301 0.7562 ± 0.0290 0.8344 ± 0.0330