Table 2.

Experimental and predicted populations of in/out/tethered gates in the 20S CP with and without the 11S RP

20S CP:11S RP* In Out In/out Tethered
1:0 Observed 28.1 ± 0.8% 71.9 ± 1.3% 0.390 ± 0.013 0%
Expected 28.6% 71.4% 0.4 0%
1:3 Observed 25.8 ± 0.5% 61.3 ± 1.8% 0.42 ± 0.02 12.9 ± 0.8%
Expected without allostery 23.8 ± 1.4% 59.0 ± 2.0% 0.40 ± 0.02 17.2 ± 2.4%
Expected with maximum allostery 11.0 ± 1.8% 71.8 ± 2.8% 0.15 ± 0.03 17.2 ± 2.4%

Observed populations are calculated from peak volumes, corrected for differential transverse relaxation. See Materials and Methods for details about concentrations used.

*

Concentrations of 20S CP and 11S RP are 22 and 65 μM, respectively. Note that there are two populations of 20S CPs, corresponding to the NMR invisible symmetric complex where both α7-rings are MII+M6A+S95C (46%), and a second 20S CP (54%) comprising one M1I+M6A+K66A+S95C α7-ring (NMR active) + one NMR inactive M1I+M6A+S95C α7-ring.